Other capabilities:
Monitor incoming TOH, POH. Monitor incoming APS messages (K1 and K2), Monitor incoming SPE pointers, Count Pointer Justifications, Detect NDF (New Data Flag) etc.
SDH
Alarm Detection: LOS, LOF, MS-AIS, MS-RDI, AU-LOP, AU-AIS, HP-RDI, HP-UNEQ, H4-LOM, TU-LOP, TU-AIS, LP-RDI, LP-UNEQ
Error Counting: Framing error, B1 BIP, B2 BIP, MS-REI, B3 BIP, HP-REI, BERT errors
Signal Traces and Labels: Regenerator Section trace (J0), Higher Order trail trace (J1), Section sync status (S1), Path signal label (C2), LP Path label (V5)
Other capabilities: Monitor incoming RS-OH, MS-OH and HO-POH, Monitor incoming APS messages (K1 and K2), Monitor incoming AU pointers. Count Pointer Justifications, Detect NDF (New Data Flag) etc.
PDH
Alarm Detection: T1: AIS, OOF, RAI E1: AIS, OOF, RAI, CAS-MFL, RMFAI T3: LOS, FERF, OOF, AIS, IDLE, RED
Add/Drop Capabilities SONET
Add/Drop to/from OC-3: STS-1, T3, E1 or T1
Add/Drop to/from STS-1: T1 or E1
SDH
Add/Drop to/from STM-1: STM-0, T3, E1 or T1
Add/Drop to/from STM-0: T1 or E1
Frequency Measurements
SONET: OC-3 or STS-1 with 1Hz discrimination, 4.6ppm accuracy
SDH: STM-1 or STM-0 with 1Hz discrimination, 4.6ppm accuracy
PDH Framing Formats
DS3/T3: C-bit Parity, M23
DS1/T1: Unframed, D4, ESF
E1: Unframed, PCM30, PCM30CRC, PCM31, PCM31CRC
Alarm and Error Logging
Alarms and Errors can be logged continuously to a file.
Coupled or Independent Settings
Transmit and Receive settings can be set as coupled to change them simultaneously or they can be set as independent.