SeSec

Please Scroll for More views 

E-mail: sales@cepoint.com

CONTACT:

Telephone: (603)883-7979

Fax: 1(603)883-3266

 

Home [Products and Solutions]

 

About Company

 

Contact us

 

Home

 

Industry News

 

Products Price List  (download)

 

Request For Quote (Form)

 

 

Rugged Portable Computer prices

 

 

RS-1702 Dual Xeon 2U Carrier Grade Enterprise Servers

 

RS-1702 Dual Opteron 2U Carrier Grade Enterprise Servers

 

CONSULTING & INTEGRATION

SOLUTIONS:

Sarbanes-Oxley Act and

Enterprise storage Overview

 

Military COTS Products

 

RAID STORAGE

 

SCSI-IDE Raid Storage

 

SCSI-SCSI Raid  System

 

SATA Raid Sub System

 

2U  Raid array

 

24 Bay Storage RAID NAS

 

iSCSI  SAN

 

IP STORAGE Raid Expansion

 

NAS (Network Attached Storage)

 

Arena Indy Disk array systems

 

Encryption/Decryption Systems

 

Portable Frame Grabber System

 

Video surveillance systems

 

Video systems

 

Uncompressed DVR with IRIG-B

time stamping (scientific imaging)

 

1U 64-bit  Dual Opteron Server

Fault-tolerant 1U server

 

CEP Cluster System Information

 

Linux Clusters

 

Beowulf  Cluster Servers

 

1U, 2U, 3U, Raid Servers,  Workstations and Nodes

 

More Rack mount systems

4U, 5U Super servers

 

42U Cluster Server Systems

 

Industrial computers

 

Field Portable lunchbox

 

RF Microwave

 

Rugged Portable Computers

 

TransPAC6300

 

Automotive color TV system

 

6.8" TFT LCD color display panel

 

Digital Video Recorder (DVR)

 

Digital Disk Recorder

 

Embedded Networking

 

Embedded  Systems

 

Homeland security appliances

 

Kiosks / NEMA 4X terminals

 

Vision and Imaging solutions

 

CCD Cameras  Surveillance DVR

 

CCD Infrared Weather proof Surveillance camera

 

Frame Grabbers / Imaging System

 

Radar Acquisition systems

 

Image and Motion Sensors

 

#1 Source for Industrial, Military, Scientific, Laboratory or Research and Development computing resources!

Non-Linear Video Editor

Plasma Display & Airport video systems

Airborne  Computers with 28V DC

Mission-Critical, High Availability Enterprise Rugged RAID Systems and NAS solutions… The ultimate RAID solution!

R-Stor- series Best Mission-Critical Enterprise Storage solutions you can rely on! The most versatile hardware & operating system compatible and reliable raid solution tailored to fit your budget!!

R-STOR™ 2.4TB to 18TB High availability RAID storage NAS solutions.  Upto 64TB (unformatted) array systems. Big Savings for Enterprise storage solutions, video streaming and Real time OLTP. Lowest cost, and high performance deployment for NAS/ SAN and IP SAN with iSCSI or Fibre Channel and SCSI Protocol support optimization. Enterprise wide data migration , or replication and data warehousing with secure world wide web or Internet access.. Applications include HDTV Video storage, Cluster storage, Massive Network file fan-out, Video Streaming and Video-On-Demand. New: SATA-II  and SAS solutions now also available

Download printable (PDF version)

Related page: Cluster Server        iSCSI & SATA NAS Storage Solutions... up to 18TB STORAGE

Cepoint   R-STOR™  , RS-212, RS316 and Rx524 Rack mount  RAID NAS Systems are built for enterprise applications,while the RMSD series are designed and manufactured for Reliability, performance and durability  in the most hostile Military or Industrial environments.

Serial ATA stand alone RAID systems, SATA to SCSI or SATA to FC-AL 2GB/s Fibre Channel  Host Bus Disk Arrays. Ideal for SAN and Enterprise Network attached , fault tolerant, clustering solutions. Space saving 2U, 3U, 4U or 5U Profile with 4, 8, 12, 14 16 and 24 -drives SATA/ATA-133/100 to SCSI or Fiber Channel  RAID  0, 1,  3, 5, 10, 30 50 and JBOD configurable options.

MISSION-CRITICAL High Performance ISCSI & NAS  STORAGE  SCALABLE  ENTERPRISE  SOLUTIONS are easy to implement, install operate & maintain. RS-316 NAS up to 12TB fault-resilient Data Server

Plug-and-play shared Raid array storage Server Sub-system, built to solve your Enterprise storage needs and, save you lots of cash and headache! R-STOR™ is built using  64-bit powerful RISC processor. This ensures 24 x7 continuous high performance, availability and reliability in high computing or mission-critical applications.                       

                   RMS-212 Rugged Mil-Std-810 Mission-Critical RAID Storage system                        Photo : (Model RMS -212 and RMS-408 )  are MIL-STD-810  Ruggedized  12- and 8-Bay FC or  iSCSI RAID Storage systems for Mission -Critical applications in Rugged hostile environments. Other models of the same series may look different. For example Model RMS-212 amd RMS-408  shown here  has horizontal and  vertical drive layout respectively)

 

(

Model RMS-408 photo shown)

OVERVIEW:    

Two Fibre Channel FC-AL (2GB/s) or SCSI-160 Host Channels or iSCSI interface to Switch fabric, LAN or Host

Two Fibre Channel or two SCSI-160  host channels with up to 16 serial ATA (SATA)/ATA-133 drives in a single storage subsystem.

Supports up to 16 or 24 SATA  (Serial ATA )compatible hard disk drives or  16  PATA  (Parallel-ATA) compatible hard disk drives

Multiple logical volumes and Drive with different RAID Level configurations

Dynamic sector repair, auto detection, auto rebuild, hot spare, and hot swap capability

Intelligent Drive Handling:

Auto sensing SATA-I or SATA-II /ATA-133/ATA-100/ATA-66

Bootable BIOS support for greater fault tolerance

S.M A.R.T disk drive monitoring for reliability

Remote browser support with password for Network management of storage arrays

SMTP support for email/ pager notification

 

SATA I or SATA-II RAID Levels:  RAID Levels support 0, 1, 3, 5, 10, 50 and JBOD

Highest capacity with performance RAID 5

Modular components:

  • Hot swappable Redundant power supply up to 650 watts output power

  • Hot swappable cooling fans

  • Hot swappable drives. Redundant or hot spare

  • Secure remote access via Web/Internet and FTP

  • Compatible with 3rd party NAS and SAN storage management products, including Veritas software,

  • Computer Associates BrightStor Backup, Brocade and EMC.

 

Enclosure Fault Management

The operating status of different subsystem components, including the power supply units, fans, controller modules and disk drives; are monitored by the subsystem. An audible alarm, and LEDs and the RAID manager software can all serve to notify onsite users of component failure. Administrators can also be notified  remotely via e-mail, SNMP, pager, or a LAN broadcast.

Photo: (Model Rx316S vertical drive config)

Rx300 or 400 SATA  series comes as 3U or 4U, 4 to 16bays or 24 bays, SCSI-SATA or SATA-to-Fibre channel FC-AL 2GB/s host bus Interface with up to 200 or 400 GB/s data transfer rate, making it one of the best blazing speed RAID Subsystem.

Disk auto rebuild. Failed drive auto rebuild Failed drive indicators Audible alarm Host independent Environment monitor Online expansion and continuous rebuild.

Consistently checks status Password protection Fax / Pager notification UPS connection Bad block auto-remapping.

 

Fibre Channel Operation Specifications:

 

Fibre Channel Data Rate 2Gb/sec, 200 MB/sec (half duplex), 400 MB/sec (full duplex)

Multi-rate Option Auto-negotiates for 1Gb or 2Gb operation

BIOS Support Bootable (Arbitrated Loop)

Topology Arbitrated Loop – public and private, fabric support (F- and FL-login)

Class FC-2 and 3

Upper Layer Protocol SCSI FCP – on-chip automation of complete SCSI I/O

Loop Initialization Completely hardware-based for high availability

Arbitrated Loop Capabilities Loop map, loop directed reset, loop broadcast

Link Diagnostics Link status indicators, internal/external loopback

Standards FC-PH, FC-AL, FC-PLDA, FCP-SCSI, FC-FS, FC-PI

 

RAID Management:

      

Browser-based JAVA, GUI (Graphical User Interface) management utility.

Self Monitoring Analysis and Reporting Technology (SMART) information is collected from the disk drives and made available locally and remotely through Disk Manager  utility, making the storage easier to manage and more reliable.

Multiple logical volumes and RAID Levels

Hot swap and hot spare supports for data availability

Transparent Storage management

 Optional SAN manager

LUN Masking

Dynamic Load Balancing

Drive failure detect

Automatic and Transparent Re-build of failed drive

Fail Over – Automatic Switching to redundant data path

Fail back – Automatic path recovery after hardware failure correction

RAID CONTROLLERS

R-STOR™ plug-and-play raid array storage sub system  has been designed to meet your current storage need and the ever growing hunger for more storage space for your enterprise. Today’s applications are faced with exponential storage growth, complex network infrastructures and tight budgets. Cepoint’s R-STOR™ storage sub system  allow you to boost storage and network capacity without adding management complexity. Comparing the low-cost and simplicity with other vendors complex and expensive systems will convince you that you have made the right choice by selecting R-STOR™ as the most cost saving and viable alternative. Cepoint’s clustering servers provide enterprise-class performance, reliability and scalability. Featuring cross-platform file sharing, seamless integration with popular management tools, extensive backup software support, hardware redundancy and advanced capabilities such as data replication and aggregation, Cepoint’s servers and storage systems will satisfy the demands of today’s evolving and demanding enterprise environments without squeezing your company’s wallet dry.


R-Stor  RMS, Rx, RA, RS and RAS300 series  Fiber Channel-to-SATA / PATA or SCSI RAID storage subsystems from Cepoint Networks combine the  cost-effective performance of SATA/ATA RAID with SCSI or Fibre bus connectivity at  1 or 2GB/s fibre or Ultra 160 SCSI performance without the high-end price.

R-STOR™ uses  RISC processor, a powerful  XOR RAID engine for high performance fail-safe, 24x7 operations. It utilizes Ultra 160 SCSI or SAN industry standard Fibre Channel or iSCSI technology, performance feature set and so can deliver reliable, high-performance data protection to support mission critical, business applications on mid and high-range RAID subsystems.

 

 

 

Features:

 

Operation System :

Linux,  Windows and Unix compatible

CPU :

Powerful RISC microprocessor

 Processor :

 RISC

RAID Level :

0,1,3,5,0+1,10, 30, 50, JBOD

RAID Architecture :

Multiple RAID

Cache Memory :

Up to 1024MB(1GB) SDRAM With ECC on board

Dual Controller Capability :

Yes (option)

Battery Backup :

Yes (option)

SCSI Architecture :

Multiple ID & Multiple LUN

SCSI or Fibre Channel to Host :

2 x FC-AL 2GB/s  ports or SCSI

SATA-I or SATA-II/ATA-133 Channel to Device :

Max. 24 /Minimum 4

Data Transfer Rate :

Up to 400MB/s

Devices support per Channel :

Up to 30 (for some SCSI-SCSI versions)

Disk Drives :

Up to 24 drives (depending on model0

Tagged Command Queuing :

Yes, up to 256 Commands

Stripe Size :

Variable

Write Option :

Write through or Write Back

Hot Swap :

Yes

Hot Spare :

Yes (rebuild Transparently & Automatically)

SAF-TE Enclosure Management :

Yes

On Line Expansion :

Yes

User Friendly GUI man :

Yes

Remote Alerts :

SMTP email/ Fax, Pager

 

Serving up your Enterprise application demands. R-Stor’s Transparent functionality ensures that your enterprise storage interoperability will help reduce cost and complexities associated with high availability in mission-critical applications requiring 24 x 7 uptime.                                   

Model RMS-408. Ruggedized MIL-STD-810 RAID system for Military and Hostile environments.

Whether you are implementing clustering using Oracle’s 9i RAC (Real Application Clustering) or just shared array storage for high availability, R-stor’s easy-to-implement features makes this a snap.Advantages include: 1) Reduced cost of lost application Services  due to unavailability of applications. 2) Increase data and system availability uptime. 3) Avoid extended downtime with implementation of clustering . 4) Easy scalability. Grow your Enterprise storage capability as the need increases


Product Specifications
Drive Bays Provided

spacing image
Free Qty

Varies (zero when fully populated from factory)

spacing image
Total drives Qty

24/16/15/14/12/11/9/8 or 4 drives (depending on P/N quoted)

spacing image
Type

Hot-swap

Cabinet

spacing image
Chassis Built-in Devices

Status Alarm indicators/Excellent cooling fans and temp management

spacing image
Chassis Form Factor

19” Rack-mountable

spacing image
Chassis Installed Devices Modules

24/16/15/14/12/11/9/8 or 4 drive options

spacing image
Chassis Supported Devices Modules

Up to 24

spacing image
Chassis Type

Heavy-duty Storage cold rolled steel cabinet

Dimensions

spacing image
Depth

26”

spacing image
Height

 1.75”(1U), 3.5”(2U), 5.25” (3U), 7” (4U) or 8.75" (5U)

spacing image
Weight

75 Lbs (approx; fully populated with 16 drives)

spacing image
Width

19” (17” without rack mount ears)

Environmental Parameters

spacing image
Humidity Range Operating

10 - 90% RH

spacing image
Max Altitude Operating

7500 Ft

spacing image
Max Operating Temperature

0 °C - 45 °C / 32°F - 115°F

spacing image
Non Operating Temperature

-25°C - 65 °C / -13° - 149°F

spacing image
Vibration Tolerance Storage

2 G @ 5-500 Hz

Shock:  Per Mil-Std-810 (for RMS-212 and RMS-408 series only)

Operating System

spacing image

 

Windows 2000/NT,  Linux, Unix AIX, operating software compatible

spacing image
Manufacturer

 Cepoint Networks, LLC

spacing image
Models available

Model 314 (14 drives, 3U) Model 315(15 drives, 3U)

Model 209(9 drives, 2U). Model 316(16 drives, 3U) Model Rx424 (24drives) , Rx416, Rx524, RAS 300 series

spacing image
Packaged Quantity

1

spacing image
Product Line

Cepoint Storage Raid array Sub-system

Host Interface Provided

spacing image
Connector Type

 2 x FC-AL (2GB/s) or 2xSCSI-Ultra160, RJ-45, RS-232, (may vary on models P/N)  2 x Ext. 68 pin type-P connector

spacing image
Interface (Storage)

Ethernet 10Base-T/100Base-TX/1000Base-T x 2

spacing image
NIC

2  (option)

Miscellaneous

spacing image
Height (Rack Units)

3U  (19”W x 5.25”H x 26” D)/ 4U (19” W x7.0”H x 26”D) / 2RU

Networking

spacing image
Compliant Standards

IEEE 802.3 802.3z 802.3U

spacing image
Data Link Protocol

Ethernet, Gigabit Ethernet, Fast Ethernet (option)

spacing image
Form Factor

Integrated  (option)

spacing image
Network Transport Protocol

TCP/IP, AppleTalk protocols, SMTP, FC and iSCSI

spacing image
Remote Management Protocol

SNMP

spacing image
Type

Embedded Network Interface Adapter

Power Supply

spacing image
Form Factor

Plug-in module

spacing image
 Frequency Required

50/60 Hz

Power Wattage (Operational)

 Redundant  Power up to 900 Watts / or 1000 Watts (non redundant)

spacing image
Type

Power supply - hot-plug / redundant

spacing image
Voltage

AC 100/240 Volts (-48V dc-dc optional)

Service

spacing image
Support Details Full Contract Period

3 year parts and labor

spacing image
Support Details Location

Factory

spacing image
Support Details Service Included

Phone consulting, Parts and labor

spacing image
Support Details Type

Technical support, Limited warranty

spacing image
Warranty

3yr on system. 3 years warranty on drives.

 

spacing image
Drive slot Type

Hot swappable dr. slots

Software

spacing image
Type

Drivers & Utilities: Windows and Linux, Unix clustering support

Storage

spacing image
Type

Hard drive array 480GB to 12TB can be daisy chained to 50TB

Storage CD/DVD

spacing image
Type

1 Slim CD-ROM (depends on model)

I/O

spacing image
Types

 2 x FC-AL (2Gb/s), RS-232,  RJ-45, 68-pin Ext U320/160 SCSI

Storage Controller

spacing image
Controller Interface Type

SATA I and II-1.5G/3.0 Gb/s or U320/ U160 SCSI

spacing image
Form Factor

Integrated or Host Bus Adapter

spacing image
Installed

1 min. 2 max Standalone/ or 1 shared